888-878-5480

Turtle & Hughes Foreign Voltage Detector With Carrying Pouch & Conductive Cap FVD/FVDPC


The Foreign Voltage Detector (FVD) tests for potentially hazardous AC voltage that may be encountered by communications technicians. The FVD warns technicians of hazardous voltage without making metallic contact. The FVD provides visual indication of the amount of AC being detected on a 10 step bar graph. An audible alarm will sound if the detected AC voltage exceeds 50 V. There are two models of leather pouches available that can be attached to the technician's tool belt. The Model FVDP is for carrying the FVD, and the Model FVDP3 is for carrying the FVD, scissors and knife. The FVD replaces the 188A test set, but it has many more features. Some of these added features are its lightweight, small size, senses voltages without making metallic contact, and suppression of 20 Hz ringing and frequencies higher than 200 Hz.
Features:

Gives advance warning on extremely hazardous voltages
Senses voltages without making metallic contact
Indicates voltage both visually and audibly
Suppresses 20 Hz ringing and frequencies higher than 200 Hz
Housed in non-conductive material
Exceeds dielectric strength test for greater than 20 KV
UL listed to U.S. and Canadian safety standards
NEBS compliant for Portable Test and Measurement Equipment
Made in USA
U.S. Patent No. 5,952,820

Specifications:

Range: 0 to 200 Vrms, Higher voltages are displayed as >200 volts
Sensing Type: AC only
Frequency: 50 to 150 Hz
Display: 10 step LED bar graph, Log response
Audible Warning Frequency: 2800 300 Hz
Audible Warning Level: Approximately 75 dba @ 1 foot
Audible Warning Threshold: >50 Vrms sensed voltage
Size: 1.7" x .9" x 7.8"
Weight: 4.8 ounces
Battery Type: One (1) 9 Volt Alkaline
Battery Life: > 9 hours continuous when idle (bar graph LED not activate)
Operating Temp: -20 C to 50 C at 10% to 95% RH, non-condensing
Storage Temp: -40 C to 85 C at 0 to 100% RH, non-condensing
Shock & Vibration: TR-EOP-000063 Compliant

Sunrise #